Almost all units in this range are mains powered units, with the exception of the TC400/28C which is a battery unit.
The RBSC and RBPS range are specifically designed and built by Red Box to provide the cleanest possible DC power unit. The products range from 25 amps up to 300 amps (if you require more please refer to our RBC5000 TRU range). The units are able to switch between two voltages, set at 14V and 28V as standard, but you may have this set at different voltages on request.
The TC400/28C is a battery powered continuous power supply allowing continuous power for a limited time only. An amber beacon is fitted to indicate low voltage on the unit. By monitoring the voltage of the unit you can also use this unit to start the aircraft.
|
| |
|
| |
 |
FEATURES
- Direct connection to aircraft or land vehicle.
- Rugged steel case.
- Fan cooled.
- User switchable between 14V and 28V.
|
|
PROTECTION
- Overload.
- Over Voltage.
- Over Current.
- Short Circuit.
PROTECTION
- EN60950-1: 2006
- Emission – EN55022-B
|
| |
|
|
|
|
|
 |
| |
|
|
 |
 |
UK |
240V 13A (STANDARD MAINS) |
USA |
110V 15A (STANDARD MAINS) |
Other Countries |
Please state country when ordering |
|
 |
|
|
|
 |
| Output Current |
25 amp |
| Output Voltage |
14.4 or 28.8 VDC |
| Output Ripple |
<250 mV |
| Input Frequency |
45 - 65 Hz |
| AC Input Supply |
95V - 270 V |
| Phase |
1Ø |
| Power Factor Correction |
Included |
| Input Rating |
880 VA |
| Dims Body (mm) |
(L) 300 x (W) 260 x (H) 110 |
| Weight |
6kg (nominal) |
|
 |
|
|
|
 |
| |
|
|
 |
 |
UK |
240V 13A (STANDARD MAINS) |
USA |
110V 15A (STANDARD MAINS) |
Other Countries |
Please state country when ordering |
|
 |
|
|
|
 |
| Output Current |
50 amp |
| Output Voltage |
14.4 or 28.8 VDC |
| Output Ripple |
<250 mV |
| Input Frequency |
45 - 65 Hz |
| AC Input Supply |
95V - 270 V |
| Phase |
1Ø |
| Power Factor Correction |
Included |
| Input Rating |
1760 VA |
| Dims Body (mm) |
(L) 520 x (W) 260 x (H) 110 |
| Weight |
10kg (nominal) |
|
 |
|
|
|
 |
| |
|
|
 |
 |
UK |
240V 13A (STANDARD MAINS) |
USA |
110V 30A |
Other Countries |
Please state country when ordering |
|
 |
|
|
|
 |
| Output Current |
75 amp |
| Output Voltage |
14.4 or 28.8 VDC |
| Output Ripple |
<250 mV |
| Input Frequency |
45 - 65 Hz |
| AC Input Supply |
95V - 270 V |
| Phase |
1Ø |
| Power Factor Correction |
Included |
| Input Rating |
2640 VA |
| Dims Body (mm) |
(L) 520 x (W) 260 x (H)210 |
| Weight |
15kg (nominal) |
|
 |
|
|
|
 |
| |
|
|
 |
 |
UK |
240V 16A |
USA |
220V 20A or 30A |
Other Countries |
Please state country when ordering |
|
 |
|
|
|
 |
| Output Current |
100 amp |
| Output Voltage |
14.4 or 28.8 VDC |
| Output Ripple |
<250 mV |
| Input Frequency |
45 - 65 Hz |
| AC Input Supply |
95V - 270 V |
| Phase |
1Ø |
| Power Factor Correction |
Included |
| Input Rating |
3500 VA |
| Dims Body (mm) |
(L) 520 x (W) 260 x (H)210 |
| Weight |
16kg (nominal) |
|
 |
|
|
|
 |
| |
|
|
|
|
 |
| Output Current |
50 amp |
| Output Voltage |
14.4 or 28.8 VDC |
| Output Ripple |
<250 mV |
| Input Frequency |
45 - 65 Hz |
| AC Input Supply |
95V - 270 V |
| Phase |
1Ø |
| Power Factor Correction |
Included |
| Input Rating |
1760 VA |
| Dims Body (mm) |
(L) 250 x (W) 420 x (H)300 |
| Weight |
16kg (nominal) |
NATO S/N 6130-99-858-8947 |
|
 |
|
| |
|
 |
UK |
240V 13A (STANDARD MAINS) |
USA |
110V 15A (STANDARD MAINS) |
Other Countries |
Please state country when ordering |
|
 |
|
|
|
 |
| |
|
|
 |
 |
UK |
240V 16A |
USA |
220V 20A or 30A |
Other Countries |
Please state country when ordering |
|
 |
|
|
|
 |
| Output Current |
100 amp |
| Output Voltage |
14.4 or 28.8 VDC |
| Output Ripple |
<250 mV |
| Input Frequency |
45 - 65 Hz |
| AC Input Supply |
95V - 270 V |
| Phase |
1Ø |
| Power Factor Correction |
Included |
| Input Rating |
3500 VA |
| Dims Body (mm) |
(L) 250 x (W) 680 x (H) 300 |
| Weight |
17kg (nominal) |
NATO S/N 6130-99-846-2299
|
|
 |
These units can be fitted with a Charge Management System that allows the user to charge their customers for the power used whilst an aircraft is connected to a Red Box RBC6000 frequency converter, RBC5000 transformer rectifier unit or and RBSC DC Power Supply. The system is an ideal platform for airport operators who want to pass on the cost of supplying ground power to aircraft on turnaround.
|
|
|
 |
| |
|
|
|
|
 |
| Output Current |
150 amp |
| Output Voltage |
14.4 or 28.8 VDC |
| Output Ripple |
<250 mV |
| Input Frequency |
45 - 65 Hz |
| AC Input Supply |
95V - 270 V |
| Phase |
1Ø & 3Ø |
| Power Factor Correction |
Included |
| Input Rating |
5280 VA |
| Dims Body Trolley Wheeled (mm) |
(L) 525 x (W) 780 x (H) 300 |
| Dims Body Case Static |
(L) 530 x (W) 580 x (H) 330 |
| Weight |
36kg/46kg (nominal) |
NATO S/N 6130-99-378-8073
|
|
 |
These units can be fitted with a Charge Management System that allows the user to charge their customers for the power used whilst an aircraft is connected to a Red Box RBC6000 frequency converter, RBC5000 transformer rectifier unit or and RBSC DC Power Supply. The system is an ideal platform for airport operators who want to pass on the cost of supplying ground power to aircraft on turnaround.

 |
Optional handle and casters (for wheeled version) |
Tow Bar |
*Specification may change without notice
|
|
 |
 |
| |
1Ph |
3Ph |
UK |
240V 32A |
3Ph 16A or 32A |
USA |
220V 20A or 30A |
3Ph 20A or 30A with
neutral |
Other
Countries |
Please state country
when ordering |
Please state country
when ordering |
|
 |
|
|
|
 |
| |
|
|
|
|
 |
| Output Current |
225 amp |
| Output Voltage |
14.4 or 28.8 VDC |
| Output Ripple |
<250 mV |
| Input Frequency |
45 - 65 Hz |
| AC Input Supply |
95V - 270 V |
| Phase |
1Ø & 3Ø |
| Power Factor Correction |
Included |
| Input Rating |
7920 VA |
| Dims Body Trolley Wheeled (mm) |
(L) 525 x (W) 780 x (H) 300 |
| Dims Body Case Static |
(L) 530 x (W) 580 x (H) 330 |
| Weight |
46kg/56kg (nominal) |
NATO S/N 6130-99-378-8073
|
|
 |
These units can be fitted with a Charge Management System that allows the user to charge their customers for the power used whilst an aircraft is connected to a Red Box RBC6000 frequency converter, RBC5000 transformer rectifier unit or and RBSC DC Power Supply. The system is an ideal platform for airport operators who want to pass on the cost of supplying ground power to aircraft on turnaround.

 |
Optional handle and casters (for wheeled version) |
Tow Bar |
*Specification may change without notice
|
|
 |
 |
| |
1Ph |
3Ph |
UK |
240V 63AA |
3Ph 16A or 32A |
USA |
N/A |
3Ph 20A or 30A with
neutral |
Other
Countries |
Please state country
when ordering |
Please state country
when ordering |
|
 |
|
|
|
 |
|
 |
|
|
|
 |
|
|
Towbar |
Longer Cable Available |
50 or 100 Amp 28vDC Power Supply |
*Specification may change without notice
|
|
 |
|
| |
| |
|
|
No Fuel, No Pollution, and No Noise
This unit is a high powered battery unit that can be used to produce continuous power. It can provide up to 110 amps for an hour, 55 amps for 2 hours, 27 amps for 3 hours etc. There is a light built into the unit that will flash when the unit needs to be charged. As long as the unit is not discharged too far it can also be used to start the aircraft. A voltmeter on the side of the unit will tell you what level the unit is at.
|
| Max amps |
3500 (Nom. short circuit current)
5200 (Max. short circuit current) |
| Capacity |
165 Amp Hrs @ 10hr rate |
| Max voltage |
30.3v DC |
| Size |
L780 W350 H300 mm |
| Weight |
140 kg |
| Operating Temp |
-40°C - + 60°C |
| Case |
Zinc Coated Steel |
| Voltage Indication |
Digital to IP65 |
| Auxiliary Protection |
Circuit breaker 50A |
| Auxiliary Input |
31V DC |
| Aircraft Cable |
3 m heavy duty |
| Charger |
20A Electronic110/230v. Charging time less than 2 hours from 50% |
| Towbar Available |
50 mm pin |
|
 |
|
|