RBC5000 - Technical Specifications |
INPUT: |
| Voltage |
380 TO 460VAC, 3-Phase with or without neutral |
| Frequency |
50Hz or 60Hz, +/- 6% |
| Current Harmonics |
EN61000-3-12 EMC – Harmonic Limits |
| Power Factor |
0.98 |
| Inrush |
Limited to 50 Amp |
| Connections |
63 Amp, 10 metre, 5 core cable with BS4343 plug or H/W |
OUTPUT: |
| Voltage |
28.5VDC |
| Voltage Regulation |
Steady-state: +/-5%, dynamic 0-100% step load: +/-15% recovering to steady-state within 50mS |
| Peak Amps RBC5400 |
400 Amps continuous and 1600 Amps peak |
| Peak Amps RBC5600 |
600 Amps continuous and 2000 Amps peak |
PROTECTION: |
| Input Protection |
63 Amp circuit breaker with current limiting |
| Thermal Overload |
Thermal sensors located in main rectifier, transformer and power module. |
SYSTEM: |
| Ambient Temperature Range |
-20 to 50 deg C |
| Humidity |
Less than 90% non condensing |
| Altitude |
All specifications are quoted at less than 2000m above sea level |
| Acoustic Noise |
Typically 65dB |
| Efficiency |
85% to 95% |
| EMC |
EN61000-3-12 EMC – Harmonic Limits
EN61000-6-2 EMC – Immunity for Industrial Environments
EN61000-6-4 EMC – Emission Standards for Industrial Environments |
| Casing |
Zinc plated steel, powder coated RAL No. BS3020. Size 103cm High x 71cm Wide x 110cm Deep without castors |
| Case Rating |
IP54 EN60529 - IP Ratings for Enclosures |
| Meters |
Analogue readout for output Amps and Volts |
| Panel |
Status lights for input and output conditions, and alarms |
VARIENTS: |
| Wheels for castor version |
Size 118cm High x 71cm Wide x 110cm Deep |
| Tow Bar |
1200mm long with 50mm eye (with trailer version only) |
| Stationary version |