Finance and Leasing
 
distributors
 
 
 

MODEL RBC4000

400Hz STATIC FREQUENCY CONVERTER
SINGLE PHASE INPUT, THREE PHASE OUTPUT

 
rbc4000

1-phase input, 3-phase output
Optional Variable Output Frequency
Optional Variable Output Voltage
Extremely Compact Case
Sophisticated LCD Display
Power Factor Corrected Input (PFC)
Galvanically Isolated Output
High Reliability IGBT Inverter

Compact 400Hz for Laboratory or Production Line:
Series RBC4000 static frequency converters have been designed for continuous duty operation in production line or laboratory applications. They will provide a high quality 3-phase, 400Hz output from almost any 50 or 60Hz utility supply, even if this supply is only single phase. The converter output is 4-wire, sinusoidal, highly regulated and galvanically isolated from the input.

Variable Frequency and Voltage Option:
As part of the testing of avionics and other aircraft equipment it is often required to vary the supply voltage and frequency in order to simulate the worst case supply quality that might be found onboard a real aircraft. Thus RBC4000 models may be ordered with control knobs that will continuously vary the output frequency from 380Hz to 420Hz and the output voltage from 97V to 132V (line to neutral). In addition, preset variations of 400Hz +/- 5% and 115V +/- 10% may be triggered by a remote PLC for automatic testing.

Only a Single Phase Supply Available? No Problem:
RBC4000 models operate as standard from a single phase supply whilst giving a 3-phase output. Both models will
operate directly from a standard European 16A (230V) supply or a UK 13A supply (the 4KVA is slightly limited on maximum power). Equally in North America a 32A, 115V, (60Hz) supply may used.

Unity Input Power Factor:
Both RBC4000 models have a power factor corrected input. This means that input power consumption is minimised and overall efficiency is maximised. This is particularly important when a limited single phase supply is being used to power the converter.

Sophisticated Digital Display:
An LCD display gives accurate information on all the major output parameters. These include output voltage (L-L and L-N), current, frequency, power factor, Kw and KVA. Each parameter may be displayed for each phase.

High Reliability IGBT Inverter:
RBC4000 units use a highly reliable IGBT based output inverter which is not only very quiet in operation, but is also able to tolerate extremely non-linear load types. Phase unbalances of up to 100% present no difficulty and the inverter has been dimensioned to withstand very large transient overloads, so that equipment with high start-up currents should rarely present a problem.

 
RBC5000 - Technical Specifications
INPUT:
Input Voltage 1-phase 230V +/-15%,
(115V toorder)
Input Frequency 50 or 60Hz, +/- 6%
Input Current Harmonics IEC 1000-3-4
Input Power Factor >0.98
Rectifier Inrush 10 second walk-in, max current < In x 1.2
Input Connections Lead and sockets or hard wire
Input Protection

Circuit breaker, rear panel

OUTPUT:
Output Voltage 115/200V or 120/208V, 3 phase + N
Output Voltage Regulation

Steady-state: +/-2%, dynamic 0-100% step load: +/-5% recovering to steady- state within 10mS

     
Variable Voltage Option

Front panel knob gives +/- 15% variation

Total Harmonic Distortion <3% linear load
Output Frequency 400Hz +/- 0.1%, quartz generated
Variable Frequency Option

Front panel knob gives +/- 5% variation

Output Phase Angle Accuracy 120 deg. +/- 1%
their mayor -0.6 to 1  
SECURITY:
Permissable Overload 10% @ 10 min, 50% @ 10 s, 150% @ 1 s
Output Overvoltage Cutout 130V L-N on any one phase
Output Undervoltage Cutout 100V L-N on any one phase
Thermal Overload Thermal sensors located in rectifier, inverter and output transformer
ENVIRONMENT & EQUIPMEMT:
Ambient Temperature Range -10 to 40 deg C
Humidity

<90%, non-condensing

Altitude

All specifications quoted at < 2000m above sea level

Acoustic Noise < 48dBA @ 1m
Overall Efficiency 85 to 91% model dependant
EMC

Better than EN55-022B

Cabinet

Zinc plated steel, powder coated RAL 7032

Cabinet Protection IP21
Meters

Digital readout for output Amps, Volts, Hz, Kw, Power Factor & KVA, for each phase

Wheels 60mm nylon, front brakes
 
Options

In standard format both models have fixed output voltage and frequency. Variable output voltage and frequency must be ordered together as an option. PLC control must also be ordered as an option.

Special output voltages are available, such as 67/115V or 254/440V for example.
Internal, 19” rack mounted version available
 
Dimensions
H380 W300 D500mm
Weight: 2.5Kva (RBC4002) - 32Kg, 4Kva
(RBC4004) - 37Kg